Configuration – opensimulator gas works park seattle

###########

The region simulator configuration is managed using a file called OpenSim.ini. This file is used regardless of whether the sim is running in standalone or grid mode. This file references some additional configuration information from the config-include/ directory. Information about the various settings is contained in the OpenSim.ini file itself (or OpenSim.ini.example for reference).

It is also possible to distribute the inifile settings over two files. la gas prices 2016 This is useful if you want to run several OpenSimulator processes where most of your settings are identical except for a few. The master file is read first, then the inifile is read. gas city indiana newspaper Settings given in the inifile overrule settings given in the master file. The master file has the same format and the same keywords as the inifile, so the same documentation applies.

Opensimulator supports the following database engines. Information about setting these up can be found in the OpenSim.ini.example file and the other various example files in bin/config-include. If you do not want to use the default SQLite configuration then you will need to setup your database before proceeding further. SQLite does not require further configuration. See Database Settings for the detailed settings.

• SQLite (default) – a lightweight database that comes bundled with OpenSimulator and can be used without requiring any extra configuration. It is mostly intended to get you up and running quickly, not for production use. It is significantly slower than MySQL. A few features here (such as attachment persistence) have not yet been fully implemented.

Running in grid mode is more complicated than running in standalone mode. It requires an understanding of UUID, X,Y location, server handshake passwords, estates and estate owners, and a couple of other settings. gas and bloating after every meal These require more care and patience to set up. wholesale electricity prices by state We strongly recommend that you don’t attempt this unless you are extremely patient and very technically proficient.

The unique ID of your region. In pretty much all cases you will want to accept the randomly generated default in the square brackets. The only time when you wouldn’t is if you were trying to set up a configuration to point to pre-existing region data. But in this case you are probably better off editing the Regions.ini file directly anyway

This is the location of the region on the grid. In standalone mode you can safely leave these as the default (1000,1000). If you were to set up additional regions later on in Regions.ini then they would need different grid co-ordinates (e.g. 1000,1001). OpenSimulator regions can be placed anywhere on a 65536 by 65536 grid, but Hypergrid enabled regions may need special consideration for region location. 100 gas vs 10 ethanol See Installing and Running Hypergrid#The 4096 Regions Limit for more information.

In virtually all cases this can be left as 0.0.0.0 (this is a wildcard that allows OpenSimulator to listen for UDP connections on any of the server’s network interfaces). If you want to restrict UDP connections to only one network interface then you can specify an explicit IP address. This address is only used internally – the External host name is the one that is actually passed to the viewer (and hence is the important one).

If you leave this at the default ‘SYSTEMIP’ then this will become the LAN network address of the machine (e.g. 192.168.1.2). This is fine if you are connecting only from within your LAN. If you want to connect to it from a client on the internet, this should be the External IP Address of your router. Fully Qualified Domain Names (FQDNs) can also be used though they will be converted to a numeric IP address before being sent to the viewer.

[test ] RegionUUID = dd5b77f8-bf88-45ac-aace-35bd76426c81 Location = 1000, 1000 SizeX = 256 SizeY = 256 SizeZ = 256 InternalAddress = 0.0 .0 .0 InternalPort = 9000 AllowAlternatePorts = False ExternalHostName = mygrid.com [test2 ] RegionUUID = dd5b77f8-bf88-45ac-aace-35bd76426c82 Location = 1000, 1001 SizeX = 256 SizeY = 256 SizeZ = 256 InternalAddress = 0.0 .0 .0 InternalPort = 9001 AllowAlternatePorts = False ExternalHostName = mygrid.com

3. The network address of the machine hosting the OpenSimulator installation must be accessible to connecting viewers. youtube gas pedal In the example above, the installation machine is reachable from the Internet via the domain name "mygrid.com". electricity diagram flow If the same installation needs to be accessed by viewers on the same network, it must be possible for them to also successfully resolve that domain name (not all routers, especially home routers, have this "loopback capability").

Be aware of loopback problems when Running viewer & server(s) on the same machine (LAN) by using the "external" configuration. ( You might notice endless waiting for region handshake.) See also troubleshoot hints. If you’re having Connectivity problems, be sure to read the Network Configuration Page. This is important if you see Region handshake issue.

[ServiceList ] AssetServiceConnector = "8003/OpenSim.Server.Handlers.dll:AssetServiceConnector" InventoryInConnector = "8003/OpenSim.Server.Handlers.dll:XInventoryInConnector" GridServiceConnector = "8003/OpenSim.Server.Handlers.dll:GridServiceConnector" GridInfoServerInConnector = "8002/OpenSim.Server.Handlers.dll:GridInfoServerInConnector" AuthenticationServiceConnector = "8003/OpenSim.Server.Handlers.dll:AuthenticationServiceConnector" OpenIdServerConnector = "8002/OpenSim.Server.Handlers.dll:OpenIdServerConnector" AvatarServiceConnector = "8003/OpenSim.Server.Handlers.dll:AvatarServiceConnector" LLLoginServiceInConnector = "8002/OpenSim.Server.Handlers.dll:LLLoginServiceInConnector" PresenceServiceConnector = "8003/OpenSim.Server.Handlers.dll:PresenceServiceConnector" UserAccountServiceConnector = "8003/OpenSim.Server.Handlers.dll:UserAccountServiceConnector" GridUserServiceConnector = "8003/OpenSim.Server.Handlers.dll:GridUserServiceConnector" FriendsServiceConnector = "8003/OpenSim.Server.Handlers.dll:FriendsServiceConnector" MapAddServiceConnector = "8003/OpenSim.Server.Handlers.dll:MapAddServiceConnector" MapGetServiceConnector = "8002/OpenSim.Server.Handlers.dll:MapGetServiceConnector"

The loginuri needs to be the address to the login service. In standalone mode, this was the same address as the region simulator and the port was 9000 by default. However, in grid mode it will be the address to login service hosted on the ROBUST instance. In this case, the address will be 192.168.1.2. The port number of 8002 is the traditional one for the grid login service and is the default in Robust.ini.example.

If you are operating a grid, then you can run different services (e.g. asset, inventory) in different ROBUST instances, in order to spread the load. electricity trading jobs To do this, you will need to edit the ServiceConnectors parameter in the [Startup] section of Robust.ini (or Robust.HG.ini if you’re running Hypergrid). The default ServiceConnectors parameter looks something like this

[ServiceList ] AssetServiceConnector = "8003/OpenSim.Server.Handlers.dll:AssetServiceConnector" InventoryInConnector = "8003/OpenSim.Server.Handlers.dll:XInventoryInConnector" GridServiceConnector = "8003/OpenSim.Server.Handlers.dll:GridServiceConnector" GridInfoServerInConnector = "8002/OpenSim.Server.Handlers.dll:GridInfoServerInConnector" AuthenticationServiceConnector = "8003/OpenSim.Server.Handlers.dll:AuthenticationServiceConnector" OpenIdServerConnector = "8002/OpenSim.Server.Handlers.dll:OpenIdServerConnector" AvatarServiceConnector = "8003/OpenSim.Server.Handlers.dll:AvatarServiceConnector" LLLoginServiceInConnector = "8002/OpenSim.Server.Handlers.dll:LLLoginServiceInConnector" PresenceServiceConnector = "8003/OpenSim.Server.Handlers.dll:PresenceServiceConnector" UserAccountServiceConnector = "8003/OpenSim.Server.Handlers.dll:UserAccountServiceConnector" GridUserServiceConnector = "8003/OpenSim.Server.Handlers.dll:GridUserServiceConnector" FriendsServiceConnector = "8003/OpenSim.Server.Handlers.dll:FriendsServiceConnector" MapAddServiceConnector = "8003/OpenSim.Server.Handlers.dll:MapAddServiceConnector" MapGetServiceConnector = "8002/OpenSim.Server.Handlers.dll:MapGetServiceConnector"

[ServiceList ] InventoryInConnector = "8003/OpenSim.Server.Handlers.dll:XInventoryInConnector" GridServiceConnector = "8003/OpenSim.Server.Handlers.dll:GridServiceConnector" GridInfoServerInConnector = "8002/OpenSim.Server.Handlers.dll:GridInfoServerInConnector" AuthenticationServiceConnector = "8003/OpenSim.Server.Handlers.dll:AuthenticationServiceConnector" OpenIdServerConnector = "8002/OpenSim.Server.Handlers.dll:OpenIdServerConnector" AvatarServiceConnector = "8003/OpenSim.Server.Handlers.dll:AvatarServiceConnector" LLLoginServiceInConnector = "8002/OpenSim.Server.Handlers.dll:LLLoginServiceInConnector" PresenceServiceConnector = "8003/OpenSim.Server.Handlers.dll:PresenceServiceConnector" UserAccountServiceConnector = "8003/OpenSim.Server.Handlers.dll:UserAccountServiceConnector" GridUserServiceConnector = "8003/OpenSim.Server.Handlers.dll:GridUserServiceConnector" FriendsServiceConnector = "8003/OpenSim.Server.Handlers.dll:FriendsServiceConnector" MapAddServiceConnector = "8003/OpenSim.Server.Handlers.dll:MapAddServiceConnector" MapGetServiceConnector = "8002/OpenSim.Server.Handlers.dll:MapGetServiceConnector"

Since OpenSimulator services are stateless (e.g. every request is unconnected with other requests as long as they affect the same persistent data where necessary), you can also load balance by starting more than one ROBUST instance with a copy of the same service (e.g. multiple asset services using the same database). Requests would be round-robined between the service copies using an HTTP reverse proxy implementation (e.g. nginx). See Performance#Services for more details.

Hypergrid is an emerging architecture supported by OpenSimulator that allows a user with an account on one standalone or grid to visit other Hypergrid-enabled standalones or grids, and for users from those grids to visit the home grid. This does not require the two installations to share a central set of data services (assets, inventory, etc.). Please see Installing and Running Hypergrid for more details.

If you’ve looked through OpenSim.ini.example or any other of the config files, you’ll see that there’s a very large number of configurable parameters spread across multiple files. See Configuring Simulator Parameters for more details about the configuration infrastructure and how settings in identically named sections (e.g. [XEngine]) are merged by OpenSimulator on loading.