That screw doesn’t have a plate/clamp on it, so I generally do go ahead and make a hook in the end e85 gas stations colorado of the wire and wrap it around. But I noticed that it has a little area that my cheaper outlets don’t have where the wire can easily slip in and be held very tightly when the screw is tightened. There are no specifics on the written instructions that come with this outlet about this, but I tested it by pulling very tightly on the wire and it seemed to hold perfectly like this. While this seems to hold very securely, I’d recommend creating a bend at the end of the wire and wrapping it around the screw.

And then the outlet is ready to be screwed into place in the junction box. This is probably the hardest part of the whole process if you’re working with 12-gauge wire. I’m telling you that those things just do not want to bend and cooperate, so it might take gas variables pogil a bit of gentle wrestling to get everything in there far enough to get the outlet screwed onto the junction box, but just be firm but gentle, and a little patient, and it’ll get there.

But that’s it! Wiring an electrical outlet is really so simple! And once it’s all wired and screwed into place, you can turn the circuit breaker back on and test the outlet to be sure that it’s all working properly. Easy peasy! And of course, you’ll want to add a face plate to finish up the job. I’m not going to do that right now because the drywall guys are still taping and mudding, and when they’re done, I’ll be priming and painting. I’ll add face plates when the walls are finished.

While I appreciate all of the work gas turbine put into this post, as a 30+ year Electrician I must point out some points of common practice, as well as some code violations. I’ll start with #12 is not the new normal in residential buildings. The average electrical box (3x2x3-1/2) is 18 cubic inches. For every colored wire count 1, for all of the ground wires count 1, and for every device count 1. In the pictures show this equals 4+1+1 or 6 conductors. For #14 each is 2 CI and for #12 it’s 2.25 CI. So using #14 would use up 12 CI while the #12 uses 13.5 CI. Adding one more #12 cable would max kansas gas service login out the box, while you could ad 2 more #14 cables. Next, electrical code requires gas emoji meaning the conductors to extend 6″ past the front of the box, so only 4″ is a code violation. I would also note here that by pigtailing the wires together you only end up with a black, white, and ground going to the outlet. This makes the installation of the outlet into the box much easier with less stress to the outlet terminals. Next is that ground splice, A crimp or wirenut is required by code, simply wrapping them together is not the right way to do it. When it comes to that ground screw, as well as any other screw terminal like it, the wire is required by code to wrap 3/4 of the way around the screw and in the direction the screw is turned to be tightened, such as twisting to the right. Lastly regarding wrapping tape around the outlet, there’s a reason Electricians don’t do it…it’s flammable. That’s right, by wrapping the tape you’re introducing a flammable material to the inside of the box, effectively defeating the entire reason for the box in the first place. I’m not trying to bash or embarrass gas and water llc anyone, I’m just try to help make sure the work is done correct and safe.